www.bnd.com.auControll-A-Door® PN1854Instruction ManualB&D Doors is a division of B&D Australia Pty Ltd ABN 25 010 473 971 Sectional Door Ope
Attaching the C-RailLocate shaft into sprocketShaftTrack bracket (x2)Fig. 07Fig. 06MARKERDOORSHUTTLEIMPORTANT NOTE: Do not power up the powerhea
Determine the Door TypeIMPORTANT NOTE: Ensure that no parts of the door extend over public footpaths or roads before installing the openerStep 4
Mounting on a Track Type DoorFig. 12TrackDoorTrackLevelLevelDoorDrilled holesStructural memberFig. 14Fig. 13Fig. 15Step 5 - Determine Bracket Position
Fig. 16Mounting on a Non-Track Type DoorHighest point of door travel25mmDoorStep LadderC-RailStep LadderHighest point of door travel25mmDoorStep Ladde
Mounting Door Bracket and ArmsStep 12.1 - Alternative Mounting OptionThe opener can be fastened to the roof by driving a bolt through the C
Setting Travel Limits NOTE: The OPERATE button will not function until the open and close limit positions are set. NOTE: If a Safety Infra-red Beam i
Fig. 27Step 15.3 - Set the Open Limit PositionPress and hold the PLUS (+) button until the door reaches the desired open limit position. Sin
Please take care when testing the Safety Obstruction Force. Excessive force may cause SERIOUS PERSONAL INJURY and/or PROPERTY DAMAGE can result from f
Fig. 31Fig. 30Fig. 32Adjusting Safety Obstruction ForceAdjusting Safety Obstruction ForceThe Safety Obstruction Force is calculated automaticall
Coding TransmittersStep 17.1 - Storing the Transmitter Code The opener can only operate from transmitters that have been programmed into it
Safety Rules 03Default Settings and Specifications 04About Your B&D Opener 05Operating Controls 06Kit Contents 08Installation 09Kn
Step 17.3 - Setting the Transmitter to Operate Vacation ModeThe opener can be programmed into a “Vacation Mode” where the opener will not re
Step 17.5 - Setting the Transmitter to Operate Pet (Pedestrian) ModeThe opener can be programmed into a “Pet Mode” where the door opens partially to a
AccessoriesTerminal BlockA variety of wired accessory items can be connected to the terminal block such as Safety Infra-red Beams, wall switch, door s
AccessoriesPWRAUXOSCCOMI R (0V)I RBLACKYELLOWREDBLACKYELLOWREDBLACKREDBLACK30V PWRP.EP.E 0VGNDOPERATEAUX OUTPUTFig. 41Fig. 42Safety Infra-red Beam (
Fig. 43How To Use Your OpenerFor maximum efficiency of your opener, your garage door must be in good operating condition. An annual service of your ga
How To Use Your OpenerManual Door OperationCAUTION: Do not open manual release in the open position, only use in the closed position. Operating the ma
If You Need a Service CallIf the opener needs service please call the dealer who installed the garage door opener (for product assista
ParametersDoor status indicatorsDoor opener state OPEN LED (green) CLOSE LED (red) BeeperOpen OnCloseOnOpening FlashingClosing FlashingDoor travel sto
MaintenanceMaintenanceThe SERVICE LED will indicate the requirement for a service and/or adjustment. To reset the SERVICE LED when the door is service
Spare PartsDiamond PD Power Drive : Instruction Manual© Copyright January 2008 B&D Doors29Controll-A-Door® P Instruction Manual
Safety RulesPlease read these important safety rulesThese safety alert symbols indicate a personal safety or property damage instruction exi
Warranty1. Definitions ‘B&D’ means (a) in Australia - B&D Doors of 17 Oasis Court, Clontarf, Queensland, 4019, a division of B&D Australia
9. Subject to paragraph 12 hereof; (i) the obligations of B&D under this warranty are limited to those contained herein and such warranties are e
www.bnd.com.au©Copyright January 2008 B&D Doors. All Rights Reserved. ® and TM are registered trademarks of B&D Australia Pty Ltd. In an ongoi
Default Settings & SpecificationsFactory default settingsDefault Step Minimum MaximumMaximum motor run time 40 seconds - - -Courtesy light time 4 m
Thank you for choosing a Controll-A-Door® P automatic garage door opener, designed and developed in Australia by B&D Doors & Openers.Th
Operating Controls01.02.03.04.05.06.07.08.09. 10.11. 12.13.PROG INPUT is used to connect the Universal Handheld Programmer to edit control and receive
Fig. 0106090708101112 13040501 02 03Diamond PD Power Drive : Instruction Manual© Copyright January 2008 B&D Doors7Controll-A-Door® P Instruction M
Kit ContentsPowerhead Unit1 x Controll-A-Door® P powerhead (Fig. 02)1 x Transmitter pack (Fig. 02) (Pack includes two keyring transmitters and batter
Knockdown C-Rail AssemblyTo AssembleUnpack and assemble the C-Rail using the steps outlined below in (Fig. 05).Fig. 05TENSION 13mm HEX BOLTDiamond PD
Comments to this Manuals